Jenis dan nama kabel
| Luas Keratan Rentas Nominal ㎡ | Penebat ketebalan mm | YJV YJY YJLV YJLY | YJV22 YJV22 YJLV23 YJLV2 3 | YIV32 YV32 YLV32 YILV32 | ||||||
| lebih kurang secara keseluruhan diameter mm | Berat kabel yang dikira | lebih kurang secara keseluruhan diameter mm | Berat kabel yang dikira | lebih kurang secara keseluruhan diameter mm | Berat kabel yang dikira | |||||
| YJV YJY | YJLV YJLY | YJV22 YJV22 | YJLV23 YJLV23 | YJLV23 YJLV23 | YJLV32 YJLV32 | |||||
| 1×25 | 3.4 | 19.2 | 560 | 一 | 23.2 | 839 | 25.2 | 935 | 一 | |
| 1×35 | 3.4 | 20.3 | 678 | 一 | 24.3 | 970 | 26.3 | 1069 | 一 | |
| 1×50 | 3.4 | 21.5 | 818 | 529 | 25.5 | 1127 | 838 | 27.5 | 1229 | 940 |
| 1×70 | 3.4 | 23.3 | 1056 | 637 | 27.1 | 1375 | 956 | 29.3 | 1495 | 1076 |
| 1×95 | 3.4 | 25.2 | 1342 | 762 | 29.0 | 1685 | 1105 | 31.2 | 1818 | 1238 |
| 1×120 | 3.4 | 26.4 | 1587 | 859 | 30.2 | 1946 | 1218 | 32.4 | 2081 | 1353 |
| 1×150 | 3.4 | 28.2 | 1887 | 988 | 32.0 | 2269 | 1370 | 34.2 | 2412 | 1513 |
| 1×185 | 3.4 | 29.8 | 2251 | 1130 | 33.6 | 2652 | 1531 | 35.8 | 2801 | 1680 |
| 1×240 | 3.4 | 32.4 | 2827 | 1359 | 37.6 | 3610 | 2142 | 38.4 | 3425 | 1957 |
| 1×300 | 3.4 | 34.9 | 3447 | 1602 | 39.9 | 4269 | 2424 | 40.9 | 4084 | 2239 |
| 1×400 | 3.4 | 37.6 | 4281 | 1916 | 42.8 | 5182 | 2817 | 44.6 | 5104 | 2739 |
| 1×500 | 3.4 | 41.1 | 5356 | 2320 | 46.7 | 6377 | 3341 | 48.1 | 6249 | 3213 |
| 1×630 | 3.4 | 45.0 | 6737 | 2828 | 50.8 | 7872 | 3963 | 54.6 | 8078 | 4169 |
| 1×800 | 3.4 | 49.1 | 8444 | 3441 | 55.1 | 9706 | 4703 | 57.7 | 9765 | 4762 |
| 1×1000 | 3.4 | 53.1 | 10243 | 4093 | 59.3 | 11630 | 5480 | 62.7 | 11795 | 5645 |
| 3×25 | 3.4 | 38.7 | 1859 | 一 | 44.6 | 2614 | 一 | 45.7 | 3479 | 一 |
| 3×35 | 3.4 | 41.3 | 2255 | — | 47.4 | 3067 | 一 | 48.3 | 3970 | 一 |
| 3×50 | 3.4 | 44.1 | 2719 | 1852 | 50.1 | 3569 | 2697 | 52.3 | 5021 | 4149 |
| 3×70 | 3.4 | 47.7 | 3454 | 2197 | 54.0 | 4392 | 3129 | 56.3 | 6002 | 4739 |
| 3×50 | 3.4 | 51.6 | 4330 | 2590 | 57.9 | 5338 | 3590 | 60.2 | 7045 | 5297 |
| 3×120 | 3.4 | 54.4 | 5140 | 2955 | 60.9 | 6197 | 4000 | 63.2 | 8017 | 5820 |
| 3×150 | 3.4 | 58.1 | 6055 | 3359 | 64.9 | 7238 | 4528 | 67.1 | 9130 | 6420 |
| 3×185 | 3.4 | 61.9 | 7271 | 3907 | 68.6 | 8453 | 5072 | 70.9 | 10515 | 7134 |
| 3×240 | 3.4 | 67.3 | 9050 | 4647 | 74.4 | 10388 | 5962 | 76.5 | 12566 | 8140 |
| 3×300 | 3.4 | 72.7 | 10993 | 5457 | 79.7 | 12419 | 6855 | 82.1 | 14825 | 9261 |
| 3×400 | 3.4 | 78.5 | 13589 | 6494 | 87.1 | 15975 | 8845 | 89.6 | 18802 | 11672 |
| 3×500 | 3.4 | 86.2 | 17026 | 7917 | 95.7 | 19720 | 10566 | 97.5 | 22745 | 13591 |
Jenis dan nama kabel
| Nominal silang- keratan luas mm2 | Penebat ketebalan mm | YJV YJY YJLV YJLY | YJV22 YJV22YJLV23 YJLV23 | YJV32 YJV32 YJLV32 YJLV32 | ||||||
| lebih kurang secara keseluruhan diameter mm | Dikira berat daripada kabel | lebih kurang secara keseluruhan diameter mm | Dikira weight daripada kabel | lebih kurang secara keseluruhan diameter mm | Dikira weight daripada kabel | |||||
| YJV YJY | YJLV YJLY | YJV22 YJV22 | YJLV23 YJLV23 | YJLV23 YJLV23 | YJLV32 YJLV32 | |||||
| 1×25 | 4.5 | 21.4 | 639 | — | 25.4 | 947 | — | 27.4 | 1049 | — |
| 1×35 | 4.5 | 22.7 | 767 | — | 26.5 | 1080 | — | 28.7 | 1199 | — |
| 1×50 | 4.5 | 23.9 | 913 | 624 | 27.7 | 1241 | 952 | 29.9 | 1368 | 1079 |
| 1×70 | 4.5 | 25.7 | 1159 | 740 | 29.5 | 1510 | 1091 | 31.7 | 1644 | 1225 |
| 1×95 | 4.5 | 27.4 | 1440 | 860 | 31.4 | 1825 | 1245 | 33.4 | 1952 | 1372 |
| 1×120 | 4.5 | 28.8 | 1701 | 973 | 32.6 | 2092 | 1364 | 34.8 | 2235 | 1507 |
| 1×150 | 4.5 | 30.4 | 1995 | 1096 | 34.4 | 2419 | 1520 | 36.4 | 2554 | 1655 |
| 1×185 | 4.5 | 32.2 | 2377 | 1256 | 37.4 | 3156 | 2035 | 38.2 | 2968 | 1847 |
| 1×240 | 4.5 | 34.8 | 2964 | 1496 | 39.8 | 3783 | 2315 | 40.8 | 3600 | 2132 |
| 1×300 | 4.5 | 37.3 | 3594 | 1749 | 42.5 | 4488 | 2643 | 44.3 | 4406 | 2561 |
| 1×400 | 4.5 | 39.8 | 4420 | 2055 | 45.2 | 5392 | 3027 | 47.0 | 5304 | 2939 |
| 1×500 | 4.5 | 43.5 | 5526 | 2490 | 49.1 | 6604 | 3568 | 50.7 | 6481 | 3445 |
| 1×630 | 4.5 | 47.4 | 6921 | 3012 | 53.4 | 8139 | 4230 | 55.8 | 8166 | 4257 |
| 1×800 | 4.5 | 51.5 | 8643 | 3640 | 57.5 | 9963 | 4960 | 60.1 | 10015 | 5012 |
| 1×1000 | 4.5 | 55.3 | 10435 | 4285 | 61.5 | 11875 | 5725 | 64.1 | 11933 | 5783 |
| 3×25 | 4.5 | 43.9 | 2160 | — | 49.9 | 3024 | — | 51.1 | 4010 | — |
| 3×35 | 4.5 | 46.2 | 2551 | — | 52.3 | 3447 | — | 54.6 | 5003 | — |
| 3×50 | 4.5 | 49.0 | 3036 | 2164 | 55.3 | 3994 | 3122 | 57.6 | 5623 | 4751 |
| 3×70 | 4.5 | 52.9 | 3812 | 2549 | 59.4 | 4865 | 3602 | 61.5 | 6606 | 5343 |
| 3×50 | 4.5 | 56.8 | 4747 | 2999 | 63.2 | 5833 | 4085 | 65.6 | 7741 | 5993 |
| 3×120 | 4.5 | 59.6 | 5546 | 3349 | 66.2 | 6711 | 4514 | 68.6 | 8693 | 6496 |
| 3×150 | 4.5 | 63.2 | 6528 | 3818 | 70.1 | 7751 | 5041 | 72.2 | 9797 | 7087 |
| 3×185 | 4.5 | 66.9 | 7728 | 4347 | 73.7 | 8985 | 5604 | 76.1 | 11206 | 7825 |
| 3×240 | 4.5 | 72.4 | 9574 | 5148 | 79.5 | 10954 | 6528 | 81.8 | 13322 | 8896 |
| 3×300 | 4.5 | 77.8 | 11572 | 6008 | 86.5 | 13880 | 8316 | 88.7 | 16685 | 11121 |
| 3×400 | 4.5 | 83.6 | 14281 | 7151 | 92.5 | 16704 | 9574 | 94.7 | 19671 | 12541 |
| 3×500 | 4.5 | 91.1 | 17640 | 8486 | 100.8 | 20456 | 11302 | 102.8 | 23644 | 14490 |
Jenis/ Nama Penggunaan utama kabel aloi aluminium siri 8030 dengan kekonduksian tinggi
| taip | Nama | Kegunaan utama |
| YJLHV | · Teras aloi aluminium bersilang polivinil bertebat polietilena kabel kuasa bersarung klorida | · Ia boleh diletakkan di dalam terowong yang tidak lembap dan ditetapkan pada sokongan, menjimatkan kos jambatan atau paip. |
| YJLHY | · Teras aloi aluminium bersilang penebat polietilena polietilena kabel kuasa bersarung | ·Ia boleh diletakkan dalam persekitaran yang kering atau lembap, dan penyokong dalaman, pendakap, tangga atau lekapan kabel boleh digunakan. Parit kabel luar, saluran demi saluran atau peletakan tertimbus terus, boleh menahan daya luaran mekanikal yang lebih besar. |
| YJLHV22 | · Teras aloi aluminium bersilang polivinil bertebat polietilena pita keluli bersarung luar klorida kabel kuasa perisai | ·Prestasi yang stabil dan boleh dipercayai, ringan, boleh diletakkan di dalam rumah, kurungan tetap, diletakkan di dalam terowong, saluran paip, parit kabel dan tanah longgar, tidak boleh menahan tindakan mekanikal luaran. |
| YJLHY23 | · Teras aloi aluminium bersilang pita keluli terlindung polietilena melapisi bahagian luar polietilena kabel kuasa bersarung | ·Prestasi yang stabil dan boleh dipercayai, boleh terus dikuburkan, boleh menahan daya luaran mekanikal tertentu, tetapi tidak boleh menahan ketegangan yang besar. |
| YJLHV32 | · Teras aloi aluminium bersilang dawai halus berpenebat polietilena melapisi luar polivinil klorida kabel kuasa bersarung | · Ia boleh diletakkan dalam persekitaran yang kering atau lembap, dan sokongan dalaman, pendakap, tangga atau lekapan kabel boleh digunakan. Di luar boleh menggunakan parit kabel, terowong atau peletakan langsung yang tertimbus, boleh menahan daya luaran mekanikal yang lebih besar. |
| YJLHY33 | · Teras aloi aluminium bersilang dawai halus berpenebat polietilena luar polietilena berperisai kabel kuasa bersarung | ·Ringan, boleh diletakkan dalam persekitaran yang kering atau lembap, dalam ruangan boleh digunakan pendakap, pendakap, tangga atau permukaan lekapan kabel; Di luar boleh menggunakan parit kabel, terowong atau peletakan langsung yang tertimbus, boleh menahan daya luaran mekanikal yang lebih besar. Dengan kalis api dan rintangan api yang sangat baik, terpulang kepada kelas A. |
Nota: Mengikut keperluan pelanggan, pengeluaran kalis api gred A, kalis api gred B kalis api gred C atau kabel aloi aluminium, model kabel sebelum menambah "ZA-, ZB- atau ZC(ZR) -"; Seperti ZA-YJLHV, ZB-YJLHV22, ZC-YJLHY. Semua jenis kabel aloi aluminium kalis api asap rendah bebas halogen, menambah "WDZA -, WDZB - atau WDZR(ZC) -" sebelum model kabel. Jika kabel aloi aluminium dengan rintangan suhu rendah -40℃ digunakan di kawasan yang mempunyai suhu ambien yang sangat rendah, tambahkan "(-40)" selepas model produk.
L